<?xml version="1.0" encoding="UTF-8"?>
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="JATS-archive-oasis-article1-4.xsd" article-type="research-article" dtd-version="1.4" xml:lang="ru">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Журнал Современные наукоемкие технологии</journal-title>
      </journal-title-group>
      <issn>1812-7320</issn>
      <publisher>
        <publisher-name>Общество с ограниченной ответственностью &amp;quot;Издательский Дом &amp;quot;Академия Естествознания&amp;quot;</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">ART-37636</article-id>
      <title-group>
        <article-title>ИССЛЕДОВАНИЕ ЧАСТОТНЫХ ХАРАКТЕРИСТИК ЭЛЕКТРОКАРДИОГРАММЫ ПРИ ПОМОЩИ ДИСКРЕТНОГО ПРЕОБРАЗОВАНИЯ ФУРЬЕ</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name-alternatives>
            <name xml:lang="ru">
              <surname>Черешнев</surname>
              <given-names>В.О.</given-names>
            </name>
          </name-alternatives>
          <name-alternatives>
            <name xml:lang="en">
              <surname>Chereshnev</surname>
              <given-names>V.O.</given-names>
            </name>
          </name-alternatives>
          <email>vitaliy-cha1999@yandex.ru</email>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <contrib contrib-type="author">
          <name-alternatives>
            <name xml:lang="ru">
              <surname>Проскурин</surname>
              <given-names>С.Г.</given-names>
            </name>
          </name-alternatives>
          <name-alternatives>
            <name xml:lang="en">
              <surname>Proskurin</surname>
              <given-names>S.G.</given-names>
            </name>
          </name-alternatives>
          <email>spros@tamb.ru</email>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <institution xml:lang="ru">Тамбовский государственный технический университет</institution>
        <institution xml:lang="en">Tambov State Technical University</institution>
      </aff>
      <pub-date date-type="pub" iso-8601-date="2019-08-28">
        <day>28</day>
        <month>08</month>
        <year>2019</year>
      </pub-date>
      <issue>8</issue>
      <fpage>89</fpage>
      <lpage>93</lpage>
      <permissions>
        <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <license-p>This is an open-access article distributed under the terms of the CC BY 4.0 license.</license-p>
        </license>
      </permissions>
      <self-uri content-type="url" hreflang="ru">https://top-technologies.ru/article/view?id=37636</self-uri>
      <abstract xml:lang="ru" lang-variant="original" lang-source="author">
        <p>В настоящей работе представлены результаты исследования, в котором были обработаны оцифрованные сигналы первого отведения стандартной электрокардиографической системы, содержащей помехи и наводки. С помощью фильтрации во временной области электрокардиограмма (ЭКГ) была очищена от шумов, что способствовало уменьшению гармонических составляющих на 25–50 %. Для представления и классификации частотных характеристик на протяжении всего обрабатываемого кардиосигнала был сглажен участок QS между зубцами P и T. Ввиду сильного воздействия на спектральный анализ большого количества острых всплесков ЭКГ получается результат, сильно отличающийся от суммы гармонических сигналов синусоидальной формы. Образовавшийся пробел между зубцами интерполирован полиномом Лагранжа, так как подобный вид интерполяции не оказывал влияния на спектр сигнала. Спектральное представление выявило пики с частотами кратными двум, 3.1 Гц и 6.2 Гц, соответствующие зубцам P и T. На основании полученных данных также были классифицированы частоты, соответствующие остальным зубцам кардиограммы. Полученные в ходе исследования данные сведены в таблицу и представляют регулярные гармоники, которые позволяют развивать адекватный количественный ЭКГ-анализ.</p>
      </abstract>
      <abstract xml:lang="en" lang-variant="translation" lang-source="translator">
        <p>This paper presents the results of a study in which cardiac signal of the first lead of a standard digital ECG system were processed. By filtering in the time domain, the cardiogram was cleared of noise that reduced influence of spectral harmonics by 25-50 %. To present and classify frequency characteristics throughout the entire cardio signal, the QS section between the P and T peaks was smoothed. Due to the influence of sharp peaks on the results of spectral analysis, a result considerably differ from the sum of sinusoidal components is observed. The gap between the peaks is interpolated by the Lagrange polynomial since it did not show an influence on the resultant spectrum. The spectral representation revealed peaks with frequencies oddly even, 3.1 Hz and 6.2 Hz, corresponding to the P and T peaks. Based on the obtained results the frequencies corresponding to the remaining peaks of the cardiogram were also classified. The obtained results were tabulated and represent as a set of regular harmonics what allows for further adequate quantitative analysis.</p>
      </abstract>
      <kwd-group xml:lang="ru">
        <kwd>электрокардиограмма</kwd>
        <kwd>компьютерная диагностика</kwd>
        <kwd>обработка сигналов</kwd>
        <kwd>обработка цифровых электрокардиограмм</kwd>
        <kwd>спектральный анализ</kwd>
        <kwd>преобразование Фурье</kwd>
        <kwd>частотные характеристики гармоник</kwd>
      </kwd-group>
      <kwd-group xml:lang="en">
        <kwd>electrocardiogram</kwd>
        <kwd>computer diagnostics</kwd>
        <kwd>signal processing</kwd>
        <kwd>digital ECG processing</kwd>
        <kwd>spectral analysis</kwd>
        <kwd>Fourier transform</kwd>
        <kwd>harmonic’s characteristics</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <ref>
        <note>
          <p>1. Данилов С.Н., Кольтюков Н.А., Петров С.В., Чернышова Т.И. Прогнозирование квазигармонического сигнала в пространстве состояний // Вестник ТГТУ. 2016. Т. 22. № 3. С. 374–380. DOI: 10.17277/vestnik.2016.03.pp.374-380.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>2. Чернышова Т.И., Третьяков В.В. Применение математического моделирования при реализации методов оценки и повышения метрологического ресурса аналоговых блоков информационно-измерительных систем // Вестник ТГТУ. 2015. Т. 21. № 3. С. 381–387. DOI: 10.17277/vestnik.2015.03.pp.381-387.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>3. Форогран М.А., Когевин А.В. Статистическое сравнение вейвлет-преобразований // Вестник ТГТУ. 2017. Т. 23. № 1. С. 61–71. DOI: 10.17277/vestnik.2017.01.pp.061-071.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>4. Уваров А.А., Пеньков П. Г., Чебуренко Д.С., Авдеева Д.К. Спектральный анализ ЭКГ // Современные техника и технологии: сборник научных трудов по материалам XVII Международной научно-практической конференции. Томск, 2011. С. 26–34.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>5. Захаров С.М., Знайко Г.Г. Спектральный анализ электрокардиосигналов // Вопросы радиоэлектроники. 2017. № 3. С. 110–115.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>6. Надворский Н.В., Юрко А.А., Владов С.И. Аналитический анализ спектральной плотности ЭКГ-сигнала // Вестник КрНУ имени Михаила Остроградского. 2013. № 6. С. 39-42.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>7. Дубровин В.И., Щедрина Т.А. Автоматизированная система анализа электрокардиограмм на основе вейвлет-технологий // Искусственный интеллект. 2010. № 4. С. 190–194.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>8. Kulessa B., Srokovski T., Drozdz S. Spectral Properties of ECG Series. The Henryk Niewodniczanski Institute of Nuclear Physics, Cracow, Poland, Annual Report. 2001. pp. 21–31.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>9. Калиниченко А.Н. О точности спектральных методов расчета показателей вариабельности сердечного ритма // Информационно-управляющие системы. 2007. № 6. С. 41–48.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>10. Рангайян Р.М. Анализ биомедицинских сигналов. Практический подход. М.: ФИЗМАТЛИТ, 2007. 440 с.</p>
        </note>
      </ref>
      <ref>
        <note>
          <p>11. Проскурин С.Г., Авcиевич Т.И., Cпектpальный анализ автоколебательной подвижноcти в изолиpованном тяже плазмодия Physarum polycephalum // Биофизика. 2014. Т. 59. № 6. С. 1143–1150.</p>
        </note>
      </ref>
    </ref-list>
  </back>
</article>
